Listed below are the common Navien fault codes as described by the boiler manufacturer along with a possible cause.
Boiler | Error / Fault Code | Fault Description |
---|---|---|
Combi and System | 003 | Ignition failure – manual reset needed |
Comb and System | 004 | False flame error – the boiler will auto-reset |
Combi and System | 012 | Flame loss – reset the boiler |
Combi and System | 016 | Heat exchanger overheated – try manually resetting the boiler |
Combi and System | 030 | Abnormal exhaust temperature – try manually resetting the boiler |
Combi and System | 046 | Abnormal operation: Heat exchanger overheating – the boiler should auto-reset |
Combi and System | 047 | Abnormal operation: Exhaust thermostat error – a manual reset is needed if it the boiler doesn’t auto-reset |
Combi and System | 060 | Abnormal operation: Dual venturi limit switch – boiler will auto-reset |
Combi and System | 109 | Abnormal operation: Fan error – the boiler needs resetting |
Combi and System | 110 | Exhaust blockage (condensate blockage) – reset the boiler |
Combi and System | 127 | Abnormal operation: Air pressure switch (APS) issue – reset the boiler |
Combi and System | 205 | Heating supply thermistor open or short circuit – boiler should auto-reset |
Combi and System | 218 | Alarm error: Heating return thermistor open or short circuit |
Combi and System | 302 | Low water pressure – boiler should auto-reset |
Combi and System | 352 | High water pressure – boiler should auto-reset |
Combi and System | 353 | Abnormal operation: Water pressure sensor error – boiler should auto-reset |
System | 407 | Abnormal operation: Hot water outlet thermistor – alarm error |
System | 421 | Abnormal operation: Cold water inlet thermistor Auto reset should automatically occur |
Combi and System | 480 | Abnormal operation: External domestic hot water (DHW) tank outlet thermistor – alarm error |
Combi and System | 515 | Abnormal operation: Relay feedback (PCB) – the boiler needs to be reset |
Combi and System | 517 | Abnormal operation: Dual in-line package (DIP) switch setting (PCB) – boiler needs to be reset |
Combi and System | 594 | Abnormal operation: EEPROM (PCB) – contact an engineer |
Combi and System | 615 | Abnormal operation: Input and memory (MCU) – try resetting the boiler |
Combi and System | 740 | Abnormal operation: Outdoor temperature sensor – boiler should automatically reset |
Combi and System | 782 | Abnormal operation: Main panel communication – boiler should auto-reset |