Ravenheat
Fault Codes

Listed below are the common Ravenheat fault codes as described by the boiler manufacturer along with a possible cause.

Ravenheat Boiler Fault Codes

Fault CodeSystem Behaviour
F73 Heating circuit pressure sensor fault
F74 Heating circuit pressure sensor fault
F76 Thermal fuse fault
F77 Fault in gas valve motor
F83 No water in the installation – the temperature does not increase when the burner is lit
F84 Permanent temperature difference betweenF flow and return heating sensors
F85 Flow and return heating sensors fault
F86 Underfloor heating contact fault
ERR User interface fault
04 Domestic hot water (DHW) sensor faulty

Ravenheat CSI 120 Boiler Error Codes

Fault CodeSystem Behaviour
17 Possible issue with fan voltage
01 Boiler failed to ignite – problem with gas valve operation, fan failing to start, ignition control board and cables
28

 

Failed low water – pressure switch or pump, possible issue with pump, incorrect system pressure or the low water switch pressure needs replacing
12 Failed heating sensor – issue with heating sensor and could need replacing
04 Failed overheat – the overheat thermostat needs checking
30 Failed flue temperature – check operating system
31 Failed flue temperature – the flue sensor needs checking or replacing
02 Failed temperature – try resetting the boiler

Ravenheat CS 80/90, WH System, WH 80/90 Boiler Error Codes

Fault CodeSystem Behaviour
E02 Problem with the pump circulation
E03 Flow sensor damaged
E04 Domestic hot water (DHW) sensor damaged
E05 Problem with fan – possibly no signal
E06 Central heating (CH) sensor is overheating
E08

 

Low water pressure
E09 Overheat sensor overheating
E10 High water pressure
E13 Software error
E21 Central heating (CH) return sensor overheating
E22 Flue sensor overheating
E23 Flue sensor damaged
E24 Central heating return sensor error – possibly damaged
E25 Main heat exchanger frozen
E29 Domestic hot water (DHW) sensor overheating error
E31 OpenTherm communication error
E41 Different flow/return temperatures
E42 Different temperature error
E43 Different temperature error
E44 Different temperature error
E46 Water pressure sensor error – could be open or short

Ravenheat HE 80/90 HE 25-30s, HE 80-98s, HE 8-98s or HE 25-30s compact

Different temperature error

Fault CodeSystem Behaviour
02E Problem with the pump circulation
03E Flow sensor damaged
04E Domestic hot water (DHW) sensor damaged
05E Problem with fan, possibly no signal
06E Central heating sensor is overheating
08E Low water pressure
09E Overheat sensor overheating
10E High water pressure error
13E Software error
21E Central heating return sensor overheating
22E Flue sensor overheating
23E Flue sensor damaged
24E Central heating return sensor error, possibly damaged
25E Main heat exchanger frozen
29E D.H/W sensor overheating error
31E OpenTherm (OT) communication error
41E Different temperature between flow and return
42E Different temperature error
43E
44E Different temperature error
46E Water pressure sensor error, could be open or short