Listed below are the common Sime fault codes as described by the boiler manufacturer along with a possible cause.
AL 02 Low water pressure in system |
Restore pressure |
Check for any leaks in the system |
AL 03 High water pressure in system |
Empty the system via the drain valve on the |
Hydraulic assembly and bring the pressure to approximately 1.2 bar |
AL 04 Domestic hot water sensor (SS) fault |
Check connections |
Replace the sensor |
AL 05 Delivery sensor (SM) fault |
Check connections |
Replace the sensor |
AL 06 No flame detection |
Check the integrity of the electrode and |
Check that it is not grounded |
Check gas availability and pressure |
Check the operation of the gas valve |
AL 07 Safety thermostat (TS) intervention |
Check the sensor or thermostat connections |
Deaerate the system |
Check the bleed valve |
Replace the sensor or the thermostat |
Check that the pump impeller is not blocked |
AL 08 Fault in the flame detection circuit |
Check the integrity of the electrode and check that it is not grounded |
Check gas availability and pressure |
Check the operation of the gas valve |
AL 09 No water circulating in the system |
Check the rotation of the system pump impeller |
Check the electrical connections |
Replace the pump |
AL 10 Auxiliary sensor fault |
Check the hydraulic configuration in the boiler |
Check the electrical connection |
AL 11 Gas valve modulator disconnected |
Check the electrical connection |
AL 12 Incorrect configuration of the open / sealed chamber |
Set the parameter tS 0.4 (Combustion configuration) to 0 |
AL 13 Exhaust sensor (SF) intervention |
Replace the smoke probe |
Contact the Technical Assistance Centre |
AL 14 Exhaust sensor (SF) fault |
Replace the smoke probe |
Check the electrical connection of the smoke probe, if the problem is not resolved, contact the Assistance Centre |
AL 15 Fan check cable disconnected |
Check the connection cable between the fan and the board |
AL 18 Condensate level fault |
Check for any clogging in the pipe which takes the condensate to the siphon |
Check that the siphon is not clogged |
AL 28 Maximum number of consecutive resets reached (6) |
Contact the Technical Assistance Centre AL 37 Fault due to low network voltage. |
Check with tester |
Contact network provider (ENEL) |
AL 40 Incorrect supply frequency detected |
Contact network provider (ENEL) |
AL 41 Flame loss more than 6 consecutive times |
Check the detection electrode |
Check the gas supply (open valve) |
Check mains gas pressure |
AL 42 Button fault |
Check that buttons are working |
AL 43 Open Therm communication fault |
Check the electrical connection of the remote control |
AL 62 Self-calibrating procedure is required |
Carry out the self calibrating procedure (see the specific section) |
AL 72 Incorrect positioning of the delivery sensor |
Check that the delivery sensor is attached to the delivery pipe |
AL 81 Block due to combustion during start-up |
Check for blockage in flue |
Bleed the air from the gas circuit |
AL 83 Irregular combustion (temporary error) |
Check for blockage in flue |
AL 96 Lockout due to flue (exhaust) blockage |
Check for blockage in flue |
Additional Functioning Faults |
Frequent relief valve intervention |
Check circuit pressure |
Check expansion vessel |
Limited production of domestic hot water |
Check the diverter valve |
Check that plate heat exchanger is clean |
Check domestic hot water circuit valve |