Listed below are the common Warmhaus fault codes as described by the boiler manufacturer along with a possible cause.
Fault Code | Possible Cause |
---|---|
rE 02 | Low water pressure in heating system – parameter is adjusted wrong |
E 03 | High water pressure due to excessive water pressure or safety valve error |
E 04 | Domestic hot water (DHW) temperature sensor failure – possible error with electronic card or the NTC sensor. |
E 05 | Temperature sensor from radiator error – electronic card detecting a failure. |
E 13 | Exhaust gas temperature sensor error – excessive temperature alarm. |
E 14 | Exhaust gas temperature sensor error – electronic card detecting an anomaly in the gas exhaust gas sensor. |
E 15 | Fan error – a fan being blocked or excessive external air pressure. |
rE 06 / rE 08 | No ignition – control gas supply line valves could be open |
rE 07 | Safety thermostat intervention from dual sensor – excessive heating occuring due to any failure during normal operation, try resetting the boiler. |
E 10 | AUX output sensor error |
E 16 | AUX return sensor failure |
E 11 | Gas valve modulator connection is broken – could be due to an internal failure. |
E 17 / E 19 | Maximum difference failure between 2 NTC temperature sensor – poor circulation. |
rE 28 | Maximum locking number reached – boiler has reached the maximum reset number (5 times in an hour) – attempt 1 reset each hour thereafter. |
E 37 | Low voltage error – voltage required for operation is too low. |
E 40 | Electricity network frequency error – fluctuation in electricity frequency. |
rE 41 | Flame loss after 6 successive ignitions – gas supply line valve being open. |
E 42 | Error with pushbutton |
E 43 | Room thermostat communication error – disconnection or communication loss in room thermostat. |
rE 44 | Gas valve error due to opening period without flame – try resetting the boiler. |
E 62 | Calibration request – boiler has detected an absence of calibration control. |
rE 72 | Delta T error – boiler failing to ignite. Could be due to a gas line valve being closed or a flue error. |
E 74 | Temperature sensor error. |
E 77 | Current values reached – check combustion values and CO2 calibration, try resetting the boiler if this fails. Either the board or the valve will need replacing. |
E 78 | Regulation current value has been reached. Try resetting the boiler, check the gas pressure and check the combustion values and CO2 calibration – if this doesn’t work the board or valve needs replacing. |
E 79 | Minimum regulation current reached – try resetting the boiler – checking the gas pressure and checking the combustion values and CO2 calibration – the board or valve might need replacing. |
rE 80 | Gas valve driver error – due to an internal failure. |
rE 81 | Ignition problem at the first start – this could be due the flue line, possible flue blockage or chimney gasket. |
rE 82 | Burning problem – due to the flue line either being blocked or chimney gasket. |
E 83 | Temporary mis-burning error – could be due to a gas pressure or flue line issue. |
E 84 | Capacity reduction for detected low gas inlet pressure – check the CO2 calibration values. |
rE 88 | Error in gas line cycle – possible gas valve component error. |
E 89 | Problem on combustion feedback signal – gas pressure needs checking. |
E 90 | Error in regulating combustion – possible error with the calibration values chimney gas valve and board. |
E 92 | Air compensation active – the CO2 values need checking, possible error with the wind presence. |
E 93 | Unable to regulate combustion – possible calibration value issue, chimney gas valve or board. |
E 94 | Low gas pressure or exhaust recirculation that could be an issue with gas pressure. |
E 95 | Intermittent combustion value caused by a possible error with electrode position or electrical connection stability. |
E 96 | Flue blockage – due to chimney and combustion values – the boiler may need a calibration. |
rE 80 | Gas valve error – possible internal error. |
rE 81 | Ignition problem at the first start – could be due to a problem with a flue line. |
rE 82 | Burning problem error – flue line error. |
E 83 | Temporary mis-burning error that may be caused by the gas pressure or flue line. |
rE 88 | Gas line cycle error – could be due to a gas valve component error. |
rE 98 | Electronic card start error. |
rE 99 | An error has been detected in the Combi, try resetting the boiler. |